HYTANBIO product portfolio
Lip, Forehead, Glabellar & Dark-Spot Microneedle Patches
Manufacturing and customization · Changzhou base

Products / Lip, Forehead, Glabellar & Dark-Spot Microneedle Patches
HYTANBIO · Changzhou base
Four targeted facial formats
Targeted facial arrays let brands select a patch footprint around the intended cosmetic application. The portfolio lists 350 needles for lip patches, 750 for forehead patches, 450 for glabellar patches and 500 for dark-spot patches. These HA configurations share a 300–1,000 µm nominal-height range, while dimensions, color, backing and thermoformed trays can be customized. Page 15 lists niacinamide and glabridin as a formulation reference for this facial group. The additional dark-spot profile on page 16 instead uses three HA molecular-weight grades, plant-derived salicin and niacinamide. Listed wear-time references are 2–4 hours for lip, forehead and glabellar formats and 3–6 hours for dark-spot formats. These values remain catalogue specifications for development discussion; they are not validated consumer directions or evidence of clinical effects. Confirm final formula, tolerance and claims before launch.

OEM / ODM configuration
Lip patch
- Array material: Hyaluronic acid (HA)
- Nominal needle height: 300–1,000 µm
- Needles per patch: 350
- Catalogue wear-time reference: 2–4 hours
- Customization: Backing, thermoformed tray, color and dimensions
Targeted facial formulation reference
Ingredient reference: Niacinamide and glabridin
A formulation reference shared by the facial-format group; final formula confirmed per project.
Listed wear time is a catalogue reference, not validated consumer directions. Confirm tolerance, safety and labeling for the finished configuration.

OEM / ODM configuration
Forehead patch
- Array material: Hyaluronic acid (HA)
- Nominal needle height: 300–1,000 µm
- Needles per patch: 750
- Catalogue wear-time reference: 2–4 hours
- Customization: Backing, thermoformed tray, color and dimensions
Targeted facial formulation reference
Ingredient reference: Niacinamide and glabridin
A formulation reference shared by the facial-format group; final formula confirmed per project.
Listed wear time is a catalogue reference, not validated consumer directions. Confirm tolerance, safety and labeling for the finished configuration.

OEM / ODM configuration
Glabellar patch
- Array material: Hyaluronic acid (HA)
- Nominal needle height: 300–1,000 µm
- Needles per patch: 450
- Catalogue wear-time reference: 2–4 hours
- Customization: Backing, thermoformed tray, color and dimensions
Targeted facial formulation reference
Ingredient reference: Niacinamide and glabridin
A formulation reference shared by the facial-format group; final formula confirmed per project.
Listed wear time is a catalogue reference, not validated consumer directions. Confirm tolerance, safety and labeling for the finished configuration.

OEM / ODM configuration
Dark-spot patch
- Array material: Hyaluronic acid (HA)
- Nominal needle height: 300–1,000 µm
- Needles per patch: 500
- Catalogue wear-time reference: 3–6 hours
- Customization: Backing, thermoformed tray, color and dimensions
Targeted facial profile
Ingredient reference: Niacinamide and glabridin
Cosmetic tone and dark-spot appearance development
Three-grade HA brightening profile
Ingredient reference: Hyaluronic acid in three molecular-weight grades, plant-derived salicin and niacinamide
Brightening and the appearance of pigmentation and dark spots
Listed wear time is a catalogue reference, not validated consumer directions. Confirm tolerance, safety and labeling for the finished configuration.


Buyer questions
Are the listed wear times finished-product directions?
They are catalogue references: 2–4 hours for lip, forehead and glabellar formats and 3–6 hours for dark-spot formats. Final directions require product-specific validation.
What needle counts distinguish the facial formats?
Lip: 350; forehead: 750; glabellar: 450; dark-spot: 500. Counts are per patch.
Portfolio specifications updated October 15, 2026 · HYTANBIO product portfolio, pages 15, 16. Final configuration and evidence requirements are agreed per project.
